{"product_id":"colpharma-thermo-green-plus-termometro","title":"COLPHARMA THERMO GREEN PLUS THERMOMETER","description":"\u003ch1\u003e COLPHARMA \u003cbr\u003e THERMO GREEN Plus \u003c\/h1\u003e \u003ch3\u003e ECOLOGICAL GALINSTAN THERMOMETER \u003c\/h3\u003e\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e CE Class I Medical Device. \u003cbr\u003e Galinstan thermometer, an alloy of Tin, Gallium, and Indium. Non-toxic. Shockproof casing with a measuring column lowering device. Practical, precise, and reliable. Completely disinfectable and waterproof. Tested to guarantee precision and tolerance of measurement limits. \u003cbr\u003e Minimum measurement range: from 35.5°C to 42.0°C \u003cbr\u003e Resolution: 0.1°C \u003cbr\u003e Operating conditions: temperature from -15°C to 42°C \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003e Before taking the temperature, ensure that the value indicated by the liquid column is below 36°C. Clean the glass thermometer before and after use. Observe the cleaning warnings. Position the thermometer on the body, depending on the desired type of measurement (axillary, rectal, and oral). After about 4 minutes, the thermometer detects body temperature. The measuring liquid in the thermometer's capillary indicates the body temperature detected on the temperature scale. Reading the temperature can be facilitated by slightly rotating the thermometer. After measurement, the indicator liquid must be brought back below 36°C. To do this, grasp the upper end of the thermometer with your index finger and thumb and shake it with about 15-20 rapid wrist movements. \u003cbr\u003e Always disinfect the thermometer before and after use. In a hospital, always have disinfection performed by experienced personnel. \u003cbr\u003e Oral measurement: The average normal temperature recorded is 37°C. Provides quick and accurate results. The thermometer bulb is placed to the left or right under the tongue. \u003cbr\u003e Rectal measurement: The average normal temperature is 37.6°C. This type of measurement is mainly used for children. The thermometer bulb is inserted into the anus (about 2 cm), applying a skin cream or baby oil to the tip of the bulb. A protective cover for the thermometer can be used. Insert the thermometer into this cover. Spread a water-soluble gel on the cover to facilitate insertion. Do not use petroleum jelly. Do not insert the tip of the thermometer more than 2 cm into the rectum. Stop the operation if any resistance is encountered. \u003cbr\u003e Axillary measurement: The average normal temperature is 36.7°C. The axillary measurement method does not provide as precise results as oral or rectal. Wipe the armpit hollow with a dry cloth. Place the thermometer bulb in the armpit hollow and press the arm against the torso. \u003cbr\u003e Easy flip: with Easy flip, you can easily reset the measured liquid of the thermometer by shaking it with less force: insert the thermometer into the Easy flip; make sure the thermometer is fixed in the two supports; hold the Easy flip by the lever between thumb and forefinger; shake the thermometer back and forth with strong, short movements until the liquid is brought back below 36°C. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eCleaning and disinfection\u003c\/b\u003e\u003cbr\u003e The thermometer has a hygienic and hermetically sealed glass casing and can be disinfected without limits. The temperature of the cleaning and disinfecting solution must not exceed 42°C. The glass thermometer can be cleaned before and after use with cold soapy water. Disinfect the thermometer with an alcohol-soaked cotton swab or cloth, or immerse the thermometer in a disinfectant solution (immersion time according to the disinfectant liquid manufacturer's instructions). In case of thermometer breakage, the spilled liquid can be collected and removed with a brush, cellulose cloth, or fabric cloth dampened with soapy water. The remnants can be disposed of in household waste. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Do not drop the thermometer or subject it to impacts. Do not bend the tip of the thermometer or bite it. Keep out of reach of children. Thermometers with damaged glass coating should no longer be used, due to the risk of injury. The child must always be supervised by an adult for the entire period of use. The Galinstan measuring liquid must not come into contact with noble or light metals, due to the risk of reaction. During measurement, take extreme care to avoid any risk of injury. The use of the thermometer does not replace medical consultation. A persistent feverish state, especially in children, must be subject to medical attention. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eStorage\u003c\/b\u003e\u003cbr\u003e Store at a temperature between -15°C and +42°C, in a dry place. \u003cbr\u003e \u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e 1 piece. \u003c\/div\u003e","brand":"COLPHARMA Srl","offers":[{"title":"Default Title","offer_id":45943195402507,"sku":"972066878","price":12.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/4683\/0859\/files\/GetDoc_4f89224c-f9e3-4146-bca1-77863a80299c.jpg?v=1727808077","url":"https:\/\/farmaonline24.it\/en\/products\/colpharma-thermo-green-plus-termometro","provider":"FarmaOnline24","version":"1.0","type":"link"}