{"product_id":"profar-apparecchio-per-aerosol-new-nebone","title":"PROFAR AEROSOL DEVICE NEW NEBONE","description":"\u003ch1\u003eNew Nebone Aerosol\u003c\/h1\u003e \u003cdiv align=\"justify\"\u003e\n\n\u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Compact aerosol, easy to use and clean, suitable for the treatment of all chronic and acute respiratory system conditions.\u003cbr\u003e \u003cbr\u003e \u003cu\u003eTechnical specifications\u003c\/u\u003e\u003cbr\u003e \u003ctable border=\"1cellspacing=0cellpadding=3\"\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e230 V\u003cbr\u003e ∼50 Hz\u003cbr\u003e 130 VA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eMax. pressure\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e1.8 ±0.3 bar\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eAir flow to compressor\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e9 l\/min approx\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eNoise level (at 1 m)\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e54 dB (A) approx\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eOperation\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eContinuous\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eOperating conditions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eTemperature: min. 10 °C, max. 40 °C\u003cbr\u003e Air humidity: min. 10%, max. 95%\u003cbr\u003e Atmospheric pressure: min. 69 kPa; max. 106 kPa\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eStorage conditions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eTemperature: min. -25 °C; max. 70 °C\u003cbr\u003e Air humidity: min. 10%; max. 95%\u003cbr\u003e Atmospheric pressure: min. 69 kPa; max. 106 kPa\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eRF7 Dual Speed Nebulizer\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eMinimum drug capacity: 2 ml\u003cbr\u003e Maximum drug capacity: 8 ml\u003cbr\u003e Operating pressure (with nebulization): 0.65 bar\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e14.5 (W) x 14 (D) x 10.5 (H) cm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eWeight\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e1.3 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003c\/table\u003e\n\n\u003cbr\u003e \u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003e Wash hands thoroughly and clean the device. The ampoule and accessories are for personal use only to avoid any risk of infection by contagion. This device is suitable for the administration of medicinal and non-medicinal substances for which aerosol administration is indicated; such substances must, however, be prescribed by a doctor. In the case of excessively dense substances, dilution with a suitable physiological solution may be necessary, according to medical prescription.\u003cbr\u003e \u003cbr\u003e During application, it is advisable to adequately protect against any dripping.\u003cbr\u003e Insert the power cable into a mains socket corresponding to the appliance's voltage. At the end of use, unplug the appliance from the mains socket; the socket must be positioned so that disconnection from the mains is not difficult. Insert the nozzle into the upper part. Insert the speed selector into the upper part. Pour the medicine prescribed by the doctor into the lower part. Close the nebulizer by turning the upper part clockwise. Connect the accessories.\u003cbr\u003e Sit comfortably holding the nebulizer, place the mouthpiece in your mouth or use the nasal attachment or mask. If using the mask accessory, place it on the face with or without the elastic band. Turn on the appliance by pressing the switch and inhale and exhale deeply. It is recommended to hold your breath for a moment after inhalation so that the inhaled aerosol droplets can settle. Then exhale slowly.\u003cbr\u003e Once the application is complete, turn off the appliance and unplug it. If, after the therapeutic session, a clear deposit of moisture forms inside the tube, disconnect the tube from the nebulizer and dry it with the compressor's ventilation; this action prevents possible mould growth inside the tube.\u003cbr\u003e \u003cbr\u003e \u003cu\u003eRF7 Dual Speed Nebulizer\u003c\/u\u003e\u003cbr\u003e Professional, fast, suitable for the administration of all types of drugs, including the most expensive ones, even in patients with chronic pathologies. Thanks to the geometries of the internal conduits of the RF7 Dual Speed nebulizer, a granulometry suitable and active for the treatment down to the lower respiratory tract has been achieved.\u003cbr\u003e To speed up the inhalatory therapy, position the speed selector button by pressing the MAX inscription with a finger. To make the inhalatory therapy more effective, press the MIN inscription on the speed selector with a finger. In this position, the speed selector acts as a valve and allows nebulization of the optimal amount of drug down to the lower respiratory tract, reducing its dispersion into the environment.\u003cbr\u003e \u003cu\u003eCleaning, sanitisation and disinfection\u003c\/u\u003e\u003cbr\u003e Turn off the appliance before any cleaning operation and unplug the mains cable from the socket.\u003cbr\u003e • Appliance and outside of the tube: use only a cloth moistened with a non-abrasive detergent free of solvents of any kind.\u003cbr\u003e • Accessories: open the nebulizer by turning the upper part anti-clockwise, detach the nozzle and the speed selector from the upper part. Then proceed according to the instructions below.\u003cbr\u003e \u003cbr\u003e 1. SANITISATION\u003cbr\u003e Before and after each use, sanitise the ampoule and accessories by choosing one of the following methods:\u003cbr\u003e - method A: sanitise the accessories under hot potable water (approx. 40 °C) with mild dishwashing detergent (non-abrasive);\u003cbr\u003e - method B: sanitise the accessories in a dishwasher with a hot cycle;\u003cbr\u003e - method C: sanitise the accessories by immersing them in a solution with 50% water and 50% white vinegar, then rinse thoroughly with hot potable water (approx. 40 °C).\u003cbr\u003e After sanitising the accessories, shake them vigorously and place them on a paper towel, or alternatively dry them with a jet of hot air (e.g. hairdryer).\u003cbr\u003e \u003cbr\u003e 2. DISINFECTION\u003cbr\u003e After sanitising the ampoule and accessories, disinfect them by choosing one of the following methods:\u003cbr\u003e - method A: obtain an electrolytic chloroxidising disinfectant, specific for disinfection, available in all pharmacies. Fill a container of suitable size to hold all the individual components to be disinfected with a solution of potable water and disinfectant, respecting the proportions indicated on the disinfectant packaging itself. Completely immerse each individual component in the solution, taking care to avoid the formation of air bubbles in contact with the components. Leave the components immersed for the period of time indicated on the disinfectant packaging, and associated with the concentration chosen for the preparation of the solution. Retrieve the disinfected components and rinse them thoroughly with warm potable water. Dispose of the solution according to the instructions provided by the disinfectant manufacturer;\u003cbr\u003e - method B: disinfect the accessories by boiling them in water for 10 minutes; use demineralised or distilled water to avoid limescale deposits;\u003cbr\u003e - method C: disinfect the accessories with a hot steam steriliser for baby bottles (not microwave). Follow the process faithfully according to the steriliser's instructions. For effective disinfection, choose a steriliser with an operating cycle of at least 6 minutes.\u003cbr\u003e After disinfecting the accessories, shake them vigorously and place them on a paper towel, or alternatively dry them with a jet of hot air (e.g. hairdryer). At the end of each use, store the appliance complete with accessories in a dry place and protected from dust.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e This appliance is also intended to be used directly by the patient.\u003cbr\u003e Prior to first use, and periodically during the product's life, check the integrity of the appliance's structure and power cable to ensure there is no damage; if damaged, do not insert the plug and immediately take the product to an authorised service centre or retailer.\u003cbr\u003e If the appliance does not perform as expected, contact an authorised service centre for clarification.\u003cbr\u003e The average expected lifespan of the accessories is 1 year; however, it is advisable to replace the ampoule every 6 months during intensive use (or sooner if the ampoule is obstructed) to always ensure maximum therapeutic efficacy.\u003cbr\u003e In the presence of children and non-self-sufficient persons, the appliance must be used under the strict supervision of an adult who has read the instruction manual.\u003cbr\u003e Some components of the appliance are small enough to be swallowed by children; keep the appliance out of reach of children.\u003cbr\u003e Do not use the supplied tubes and cables outside of their intended use, as they could cause a strangulation hazard. Pay particular attention to children and people with special difficulties, as these people are often unable to correctly assess dangers.\u003cbr\u003e This appliance is not suitable for use in the presence of a flammable anaesthetic mixture with air, or with oxygen or with nitrous oxide.\u003cbr\u003e Always keep the power cable away from hot surfaces.\u003cbr\u003e Keep the power cable away from animals (e.g. rodents), otherwise, such animals could damage the insulation of the power cable.\u003cbr\u003e Do not handle the appliance with wet hands. Do not use the appliance in humid environments (e.g. while bathing or showering). Do not immerse the appliance in water; if this happens, unplug it immediately. Do not remove or touch the appliance immersed in water; first, unplug it. Immediately take it to an authorised service centre or retailer.\u003cbr\u003e Use the appliance only in dust-free environments, otherwise, the therapy could be compromised.\u003cbr\u003e Do not wash the appliance under running water or by immersion and keep it away from splashes of water or other liquids.\u003cbr\u003e Do not expose the appliance to particularly extreme temperatures.\u003cbr\u003e Do not place the appliance near heat sources, sunlight or in excessively hot environments.\u003cbr\u003e Do not obstruct or insert objects into the filter and its relative housing in the appliance.\u003cbr\u003e Never obstruct the ventilation slots located on both sides of the appliance.\u003cbr\u003e Always operate the aerosol on a rigid, unobstructed surface.\u003cbr\u003e Check that there is no material obstructing the ventilation slots before each use.\u003cbr\u003e Do not insert any objects into the ventilation slots.\u003cbr\u003e Repairs, including the replacement of the power cable, must only be carried out by authorised personnel, following the information provided by the manufacturer. Unauthorised repairs void the warranty and may pose a danger to the user.\u003cbr\u003e Do not modify this appliance without the manufacturer's authorisation.\u003cbr\u003e The materials used in contact with medicines have been tested with a wide range of medicines. However, given the variety and continuous evolution of medicines, it is not possible to exclude interactions. It is advisable to consume the medicine as soon as possible once opened and to avoid prolonged exposure to the ampoule. The materials used in the medical device are biocompatible and comply with the mandatory regulations of Directive 93\/42 EC and subsequent amendments; however, it is not possible to completely exclude possible allergic reactions.\u003cbr\u003e The manufacturer should be contacted to report problems and\/or unexpected events related to operation and, if necessary, for clarification regarding use and\/or maintenance\/cleaning.\u003cbr\u003e The time required to switch from storage to operating conditions is approximately 2 hours.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e The package contains:\u003cbr\u003e - aerosol device;\u003cbr\u003e - paediatric mask;\u003cbr\u003e - adult mask;\u003cbr\u003e - mouthpiece;\u003cbr\u003e - nasal attachment;\u003cbr\u003e - RF7 Dual Speed ampoule.\u003c\/div\u003e","brand":"FEDERFARMA.CO SpA","offers":[{"title":"Default Title","offer_id":52818482430219,"sku":"974113413","price":33.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/4683\/0859\/files\/GetDoc_908b3370-afdd-46c7-9698-857e4a37ab60.jpg?v=1768226756","url":"https:\/\/farmaonline24.it\/en\/products\/profar-apparecchio-per-aerosol-new-nebone","provider":"FarmaOnline24","version":"1.0","type":"link"}