{"product_id":"test-antigenico-rapido-covid-19-autodiagnostico-determinazione-qualitativa-antigeni-sars-cov-2-in-tamponi-nasali-mediante-immunocromatografia","title":"COVID-19 RAPID ANTIGEN SELF-TEST QUALITATIVE DETECTION OF SARS-COV-2 ANTIGENS IN NASAL SWABS BY IMMUNOCHROMATOGRAPHY","description":"\u003ch1\u003eSARS-CoV-2 Antigen Rapid Test\u003c\/h1\u003e \u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e A rapid test intended for the qualitative detection of SARS-CoV-2 antigen (nucleocapsid protein) found in nasal cavity (anterior nasal) samples from individuals with suspected COVID-19 infection. The test kit is intended for self-testing or home testing.\u003cbr\u003e This test employs immune lateral chromatography technology. When the test sample contains SARS-CoV-2, the SARS-CoV-2 antigen will react with the antibody coated on the test line (T) causing a red band to appear in the test line area (T); when the SARS-CoV-2 content in the test sample is too low or non-existent, no red band appears in the test line area (T). Regardless of whether the test sample contains SARS-CoV-2, a red band will appear in the quality control line area (C), which is the basis for judging whether the test is effective.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003e 1. Use the test kit at room temperature (15°C-30°C). If the kit has been previously stored in a cool place (temperature below 15°C), equilibrate to 15°C-30°C for 30 minutes before testing.\u003cbr\u003e 2. Prepare a timer, tissues, hand sanitizer\/soap and warm water.\u003cbr\u003e 3. Wash hands thoroughly (at least 20 seconds) with soap and warm water\/hand sanitizer. Then dry hands.\u003cbr\u003e 4. Check the components in the box and ensure there is no damage or breakage.\u003cbr\u003e Sample collection:\u003cbr\u003e 1. Take out the sample extraction tube; unscrew the cap of the tube.\u003cbr\u003e 2. Place the extraction tube on the stand (attached to the box) to prevent liquid spills.\u003cbr\u003e 3. Tear the swab package from the stick end and take out the swab.\u003cbr\u003e 4. Insert the soft head of the swab into the nostril less than 1 inch; gently rotate the swab against the nasal wall with moderate force at least five times; use the same swab to repeat the collection procedure in the other nostril.\u003cbr\u003e Sample processing:\u003cbr\u003e 1. Take out the extraction tube, immerse the soft head of the swab in the extraction solution and submerge it in the liquid.\u003cbr\u003e 2. Firmly press the soft head of the swab against the inner wall of the extraction tube and rotate the swab clockwise or anti-clockwise about 10 times.\u003cbr\u003e 3. Push the swab head along the inner wall of the sample extraction tube below the liquid in the tube as much as possible, then remove the swab.\u003cbr\u003e 4. Tighten the tube cap for standby.\u003cbr\u003e Sample testing:\u003cbr\u003e 1. Tear open the aluminum foil pouch, take out the test card and place it horizontally on the test bench.\u003cbr\u003e 2. Disconnect the cap of the sample addition hole of the extraction tube.\u003cbr\u003e 3. Gently squeeze the extraction tube and drop 2 drops of liquid into the sample well of the test card.\u003cbr\u003e 4. Start timing, read the test results at 15 minutes. Do not read before 15 minutes or after 30 minutes.\u003cbr\u003e 5. After the test is completed, place all kit materials in the biohazard waste bag and dispose of them according to local biohazard waste disposal policy.\u003cbr\u003e 6. Rinse hands thoroughly for at least 20 seconds with soap and warm water\/hand sanitizer.\u003cbr\u003e Negative: The quality control line (C line) appears as a red band, while the test line (T line) does not appear as a red band.\u003cbr\u003e Positive: Both the quality control line (C line) and the test line (T line) appear as red bands.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e 1. For in vitro diagnostic use only.\u003cbr\u003e 2. To be used with nasal cavity (anterior nasal) swab samples.\u003cbr\u003e 3. For the detection of SARS-CoV-2 proteins only, not for detecting other viruses or pathogens.\u003cbr\u003e 4. Individuals under 18 years of age must be tested with the assistance of a legal guardian or authorized person.\u003cbr\u003e 5. Keep the test kit or kit components out of reach of children and pets before and after use.\u003cbr\u003e 6. The test card package contains a desiccant, do not eat.\u003cbr\u003e 7. The sample extraction solution in the extraction tube contains chemical components. Direct contact should be avoided and eating is prohibited. If the solution comes into contact with skin, mucous membranes or eyes, rinse with plenty of water. Please contact your family doctor or a professional or seek medical advice if necessary.\u003cbr\u003e 8. The use of gloves and other protective equipment is recommended when performing tests.\u003cbr\u003e 9. Test kits must be stored according to the storage conditions required in the instructions for use. It is forbidden to use a test kit that has not been stored as required.\u003cbr\u003e 10. Do not use the test kit beyond the expiration date.\u003cbr\u003e 11. Do not use kit components that have been opened or altered.\u003cbr\u003e 12. Leave the test card sealed in the aluminum foil pouch until just before use. Do not use if the pouch is damaged or opened.\u003cbr\u003e 13. Disposable swabs are sterile products. Do not use if the swab package is damaged or opened.\u003cbr\u003e 14. Swab use must strictly follow the instructions for use; otherwise, it may cause nasal cavity bleeding, swab breakage and retention, and other risks.\u003cbr\u003e 15. Do not immerse the swab in extraction solution or other liquid before collecting the sample with disposable swabs.\u003cbr\u003e 16. Do not touch the soft tip of the swab when handling the swab sample.\u003cbr\u003e 17. Proper sample collection and handling are crucial for accurate results.\u003cbr\u003e 18. Do not mix components from different kit lots.\u003cbr\u003e 19. All kit components are single-use items. Do not use with multiple samples. Do not reuse the test kit or used kit components.\u003cbr\u003e 20. Before deciding to implement relevant therapeutic or management decisions, it is recommended to communicate with family doctors or professionals. Do not take medicine privately or take any action that could endanger yourself.\u003cbr\u003e 21. Used test components and samples can be placed in plastic bags along with normal household waste. If the test result is positive, carefully dispose of waste components and relevant samples and thoroughly clean and disinfect the work surface to ensure hygiene. If there are special waste requirements in local laws and regulations, they must be strictly observed.\u003cbr\u003e 22. Do not eat, drink or smoke in the area where samples or test kits are handled.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eStorage\u003c\/b\u003e\u003cbr\u003e Store between 2°C and 30°C, in a dry place away from direct sunlight (do not freeze the kit or its components).\u003cbr\u003e Shelf life unopened: 12 months.\u003cbr\u003e Shelf life after opening: 60 minutes.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Main kit components:\u003cbr\u003e - Test device.\u003cbr\u003e - Extraction tube.\u003cbr\u003e - Disposable swab.\u003cbr\u003e - Biohazard waste bag.\u003cbr\u003e - Instructions for use. \u003c\/div\u003e","brand":"DIDOFA' Srl","offers":[{"title":"Default Title","offer_id":45945462096139,"sku":"983776713","price":1.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/4683\/0859\/files\/GetDoc_b3ab457c-5a5f-40e6-b482-555ea9839be9.jpg?v=1727819985","url":"https:\/\/farmaonline24.it\/en\/products\/test-antigenico-rapido-covid-19-autodiagnostico-determinazione-qualitativa-antigeni-sars-cov-2-in-tamponi-nasali-mediante-immunocromatografia","provider":"FarmaOnline24","version":"1.0","type":"link"}