PULSE OXYMETER OXY-2
Description
The Fingertip Pulse Oximeter is a non-invasive device designed for the spot-check of arterial hemoglobin saturation (SpO2) and pulse rate in adults and children in home and hospital environments (including clinical use in internal medicine/surgery, anesthesia, and intensive care, etc.).
It is not intended for continuous monitoring.
It is compact, easy to use and transport, and has low power consumption. The two AAA batteries provided can be used continuously for 24 hours.
Automatic shutdown when no signal is received within 5 seconds.
Low battery indicator as a flashing battery icon.
The patient simply inserts their fingertip into the photoelectric sensor of the device, and the Hemoglobin Saturation value immediately appears on the screen.
Technical Specifications:
- Display format: Digital tube display;
- Screen type: LED;
- SpO2 measurement range: 0%-100%;
- Pulse rate measurement range: 30 bpm - 250 bpm;
- Pulse rate intensity display: Bar display;
- Power requirements: 2 x 1.5 V AAA alkaline batteries; adaptable range: 2.6 V - 3.6 V;
- Supply current: less than 25 mA;
- Resolution: 1% for SpO2 and 1 bpm for pulse rate;
- Measurement accuracy: ±2% in the 70%-100% SpO2 phase, and irrelevant when the phase is less than 70%. ±2 bpm or ±2% (whichever is greater) for pulse rate;
- Measurement performance in low perfusion conditions: SpO2 and pulse rate are displayed correctly when the pulse-filling ratio is 0.4%. SpO2 error ±4%, pulse rate error ±2 bpm or ±2% (whichever is greater);
- Tolerance to external light: The difference between the value detected in the presence of artificial light, indoor natural light, and that of a dark room is less than ±1%;
- It has a function switch. The Pulse Oximeter turns off if no finger is detected in the device;
- Optical sensor: red light (wavelength is 660 nm, 6.65 mW) and infrared (wavelength is 880 nm, 6.75 mW);
- Operating environment:
Temperature: 10°C - 40°C
Relative humidity: ≤75%
Atmospheric pressure: 700 hPa - 1,060 hPa.
Note: The optical sensor is a light-emitting component that affects other medical devices by applying the same range of wavelengths.
Instructions for use
Insert the two batteries in the correct direction and then replace the cover. Open the sensor. Have the patient insert their finger into the rubber-coated sensor (make sure the finger is in the correct position), then allow the sensor to close on the finger. Press the power button on the front panel. Do not move the finger and keep the patient at rest during measurement. Furthermore, the patient is advised not to move. Measurement results are displayed directly on the screen.
In the device's startup state, press the button and the device will be reset.
Nails and the light-emitting tube must remain on the same side.
Cleaning and maintenance: Replace batteries when the low battery indicator begins to flash.
Clean the device surface before use. Wipe with medical alcohol first, then allow to air dry or wipe dry.
Use medical alcohol to disinfect the product after use, this prevents contamination for subsequent use.
If the Pulse Oximeter is not used for a long period, remove the batteries.
The device must be calibrated regularly (or according to the hospital's calibration schedule).
Do not sterilize the device with high pressure.
Warnings
The finger must be positioned appropriately, otherwise this may lead to inaccurate measurements.
The SpO2 sensor and the photoelectric receiving tube must be positioned so that the patient's arteriole is in a position between the two.
The SpO2 sensor must not be used in an area or on a limb tied with a blood pressure cuff or during an intravenous injection.
Ensure that the optical path is free of optical obstructions, such as rubberized tissue.
Excessive ambient light can affect the measurement result. This includes fluorescent lamps, dual red lights, infrared heaters, direct sunlight, etc.
Strenuous patient activity or extreme electro-surgical interference can also affect accuracy.
The patient undergoing the examination cannot wear nail polish or other cosmetics.
Do not immerse the device in any type of liquid.
It is recommended to keep the device in a dry environment. Humidity could reduce the device's lifespan or even damage it.
Explosion hazard: Do not use the Pulse Oximeter in environments with the presence of flammable gases such as some flammable anesthetic agents.
DO NOT use the Pulse Oximeter while the patient is undergoing MRI or CT scans.
A person allergic to rubber cannot use this device.> Please check the packaging before use to ensure that the device and its accessories fully comply with the packing list, otherwise the device may malfunction.
Please do not measure this device with paper functional tests for relevant device information.
Keep the Pulse Oximeter away from dust, vibrations, corrosive substances, explosive materials, high temperatures, and humidity.
If the Pulse Oximeter gets wet, please stop using it.
When transported from a cold environment to a warm or humid environment, do not use it immediately.
DO NOT press the front panel buttons with sharp objects.
Disinfection of the Pulse Oximeter with high-temperature steam or pressure is not permitted. Do not immerse the Pulse Oximeter in liquids. When cleaning is needed, wipe its surface with a soft cloth dampened with medical alcohol. Do not spray liquids directly onto the device. When cleaning the device with water, the temperature must be below 60°C.
Since fingers that are too thin or too cold may affect the normal SpO2 and pulse rate measurement of the patient, place thicker fingers, such as the thumb and middle finger, deep enough into the device.
Do not use the device on infants or newborns. The device is suitable for children over four years old and adults (weight must be between 15 and 110 kg).
The device may not work for all patients. If stable measurements cannot be achieved, discontinue use.
The data update period is less than 5 seconds: this duration varies based on individual heart rates.
If any abnormality appears on the screen during the testing procedure, remove the finger and reinsert it to restore normal use.
The normal lifespan of the device is three years from the first power-on.
The support lanyard attached to the product is made of hypoallergenic material; if a particular group is allergic to the support lanyard, stop using it. Additionally, be careful when using the support lanyard; do not hang it around the neck to avoid injury to the patient.
The device does not have a low voltage alarm function; it only indicates the battery charge level. Please change the battery when the power level is depleted.
The device does not have an alarm function for particularly low parameters. Do not use the device in situations where alarms are required.
Batteries must be removed if the device is stored for more than one month, otherwise they may leak liquid.
A flexible circuit connects the two parts of the device. Do not twist or pull the connection.
Storage
Store between -40°C and 60°C. Relative humidity: ≤95%
Format
1 piece.
Code. 35072
The Fingertip Pulse Oximeter is a non-invasive device designed for the spot-check of arterial hemoglobin saturation (SpO2) and pulse rate in adults and children in home and hospital environments (including clinical use in internal medicine/surgery, anesthesia, and intensive care, etc.).
It is not intended for continuous monitoring.
It is compact, easy to use and transport, and has low power consumption. The two AAA batteries provided can be used continuously for 24 hours.
Automatic shutdown when no signal is received within 5 seconds.
Low battery indicator as a flashing battery icon.
The patient simply inserts their fingertip into the photoelectric sensor of the device, and the Hemoglobin Saturation value immediately appears on the screen.
Technical Specifications:
- Display format: Digital tube display;
- Screen type: LED;
- SpO2 measurement range: 0%-100%;
- Pulse rate measurement range: 30 bpm - 250 bpm;
- Pulse rate intensity display: Bar display;
- Power requirements: 2 x 1.5 V AAA alkaline batteries; adaptable range: 2.6 V - 3.6 V;
- Supply current: less than 25 mA;
- Resolution: 1% for SpO2 and 1 bpm for pulse rate;
- Measurement accuracy: ±2% in the 70%-100% SpO2 phase, and irrelevant when the phase is less than 70%. ±2 bpm or ±2% (whichever is greater) for pulse rate;
- Measurement performance in low perfusion conditions: SpO2 and pulse rate are displayed correctly when the pulse-filling ratio is 0.4%. SpO2 error ±4%, pulse rate error ±2 bpm or ±2% (whichever is greater);
- Tolerance to external light: The difference between the value detected in the presence of artificial light, indoor natural light, and that of a dark room is less than ±1%;
- It has a function switch. The Pulse Oximeter turns off if no finger is detected in the device;
- Optical sensor: red light (wavelength is 660 nm, 6.65 mW) and infrared (wavelength is 880 nm, 6.75 mW);
- Operating environment:
Temperature: 10°C - 40°C
Relative humidity: ≤75%
Atmospheric pressure: 700 hPa - 1,060 hPa.
Note: The optical sensor is a light-emitting component that affects other medical devices by applying the same range of wavelengths.
Instructions for use
Insert the two batteries in the correct direction and then replace the cover. Open the sensor. Have the patient insert their finger into the rubber-coated sensor (make sure the finger is in the correct position), then allow the sensor to close on the finger. Press the power button on the front panel. Do not move the finger and keep the patient at rest during measurement. Furthermore, the patient is advised not to move. Measurement results are displayed directly on the screen.
In the device's startup state, press the button and the device will be reset.
Nails and the light-emitting tube must remain on the same side.
Cleaning and maintenance: Replace batteries when the low battery indicator begins to flash.
Clean the device surface before use. Wipe with medical alcohol first, then allow to air dry or wipe dry.
Use medical alcohol to disinfect the product after use, this prevents contamination for subsequent use.
If the Pulse Oximeter is not used for a long period, remove the batteries.
The device must be calibrated regularly (or according to the hospital's calibration schedule).
Do not sterilize the device with high pressure.
Warnings
The finger must be positioned appropriately, otherwise this may lead to inaccurate measurements.
The SpO2 sensor and the photoelectric receiving tube must be positioned so that the patient's arteriole is in a position between the two.
The SpO2 sensor must not be used in an area or on a limb tied with a blood pressure cuff or during an intravenous injection.
Ensure that the optical path is free of optical obstructions, such as rubberized tissue.
Excessive ambient light can affect the measurement result. This includes fluorescent lamps, dual red lights, infrared heaters, direct sunlight, etc.
Strenuous patient activity or extreme electro-surgical interference can also affect accuracy.
The patient undergoing the examination cannot wear nail polish or other cosmetics.
Do not immerse the device in any type of liquid.
It is recommended to keep the device in a dry environment. Humidity could reduce the device's lifespan or even damage it.
Explosion hazard: Do not use the Pulse Oximeter in environments with the presence of flammable gases such as some flammable anesthetic agents.
DO NOT use the Pulse Oximeter while the patient is undergoing MRI or CT scans.
A person allergic to rubber cannot use this device.> Please check the packaging before use to ensure that the device and its accessories fully comply with the packing list, otherwise the device may malfunction.
Please do not measure this device with paper functional tests for relevant device information.
Keep the Pulse Oximeter away from dust, vibrations, corrosive substances, explosive materials, high temperatures, and humidity.
If the Pulse Oximeter gets wet, please stop using it.
When transported from a cold environment to a warm or humid environment, do not use it immediately.
DO NOT press the front panel buttons with sharp objects.
Disinfection of the Pulse Oximeter with high-temperature steam or pressure is not permitted. Do not immerse the Pulse Oximeter in liquids. When cleaning is needed, wipe its surface with a soft cloth dampened with medical alcohol. Do not spray liquids directly onto the device. When cleaning the device with water, the temperature must be below 60°C.
Since fingers that are too thin or too cold may affect the normal SpO2 and pulse rate measurement of the patient, place thicker fingers, such as the thumb and middle finger, deep enough into the device.
Do not use the device on infants or newborns. The device is suitable for children over four years old and adults (weight must be between 15 and 110 kg).
The device may not work for all patients. If stable measurements cannot be achieved, discontinue use.
The data update period is less than 5 seconds: this duration varies based on individual heart rates.
If any abnormality appears on the screen during the testing procedure, remove the finger and reinsert it to restore normal use.
The normal lifespan of the device is three years from the first power-on.
The support lanyard attached to the product is made of hypoallergenic material; if a particular group is allergic to the support lanyard, stop using it. Additionally, be careful when using the support lanyard; do not hang it around the neck to avoid injury to the patient.
The device does not have a low voltage alarm function; it only indicates the battery charge level. Please change the battery when the power level is depleted.
The device does not have an alarm function for particularly low parameters. Do not use the device in situations where alarms are required.
Batteries must be removed if the device is stored for more than one month, otherwise they may leak liquid.
A flexible circuit connects the two parts of the device. Do not twist or pull the connection.
Storage
Store between -40°C and 60°C. Relative humidity: ≤95%
Format
1 piece.
Code. 35072