ACCU-CHEK
Guide
25 Strips Retail
Description
Accu-Chek Guide is a blood glucose monitoring system indicated for people with diabetes for home self-monitoring and for in vitro diagnostic use by healthcare professionals in a clinical setting.
The Accu-Chek Guide system is a unique solution, designed to meet the diverse needs of people with diabetes and healthcare professionals. The system's features, such as the patented oval spill-resistant vial and the new test strips with a wide blood sample application area, represent intelligent solutions that simplify blood glucose testing.
The system offers excellent accuracy and precision. Accu-Chek Guide test strips have undergone a wide variety of tests, including studies conducted at external sites and in-depth internal tests. The study results show that the test strips provide accurate and reliable measurements under various conditions.
Accu-Chek Guide strips boast three main features:
- Oval spill-resistant vial: the innovative design of the strip container prevents spillage and facilitates the removal of only one strip at a time. Its oval shape makes it pocket-sized, and the protruding cap is easy to open.
- Wide blood sample application area: the new Accu-Chek Guide test strips allow a small blood sample to be applied anywhere on the wide yellow-highlighted tip, intuitively marked by red blood droplets near the area.
- Excellent accuracy (10/10): the Accu-Chek Guide system complies with ISO 15197:2013/EN ISO 15197:2015 and offers accuracy superior to the required standards, ensuring reliable results.
Technical specifications:
System Accuracy:
1. System accuracy results for glucose concentrations below 100 mg/dL (below 5.55 mmol/L):
- within ±5 mg/dL (within ±0.28 mmol/L): 175/186 (94.1%);
- within ±10 mg/dL (within ±0.56 mmol/L): 186/186 (100%);
- within ±15 mg/dL (within ±0.83 mmol/L): 186/186 (100%).
2. System accuracy results for glucose concentrations at or above 100 mg/dL (at or above 5.55 mmol/L):
- within ±5 mg/dL: 296/414 (71.5%);
- within ±10 mg/dL: 404/414 (97.6%);
- within ±15 mg/dL: 413/414 (99.8%);
3. System accuracy results for glucose concentrations between 14 mg/mL (0.78 mmol/L) and 578 mg/mL (32.1 mmol/L):
- within ±15 mg/dL or within ±15% (within ±0.83 mmol/L or within ±15%): 599/600 (99.8%).
Components
Reagent composition:
Mediator 6.6%;
FAD-GDH Enzyme 21.3%;
Buffer 22.6%;
Stabilizer 0.3%;
Non-reactive component 49.2%;
How to use
Carefully read the test strip leaflet.
Place the sample on the strip's aspiration area, highlighted in yellow. Wait approximately 4 seconds for the measurement cycle to complete.
The yellow reactive zone on the strip provides visual confirmation of correct sample application.
Warnings
Lipemic samples (triglycerides) >1800 mg/dL (>20.3 mmol/L) may produce elevated blood glucose results.
Do not use this system if you are receiving an intravenous ascorbic acid infusion.
Do not use this system during a xylose absorption test.
Storage
Store the strips at a temperature between 4°C and 30°C.
Test strips can be used until the expiry date indicated on the packaging.
This applies to test strips in a new and intact vial, as well as to test strips in an already opened vial.
Format
Pack of 25 strips.
Code. 08137358001
Accu-Chek Guide is a blood glucose monitoring system indicated for people with diabetes for home self-monitoring and for in vitro diagnostic use by healthcare professionals in a clinical setting.
The Accu-Chek Guide system is a unique solution, designed to meet the diverse needs of people with diabetes and healthcare professionals. The system's features, such as the patented oval spill-resistant vial and the new test strips with a wide blood sample application area, represent intelligent solutions that simplify blood glucose testing.
The system offers excellent accuracy and precision. Accu-Chek Guide test strips have undergone a wide variety of tests, including studies conducted at external sites and in-depth internal tests. The study results show that the test strips provide accurate and reliable measurements under various conditions.
Accu-Chek Guide strips boast three main features:
- Oval spill-resistant vial: the innovative design of the strip container prevents spillage and facilitates the removal of only one strip at a time. Its oval shape makes it pocket-sized, and the protruding cap is easy to open.
- Wide blood sample application area: the new Accu-Chek Guide test strips allow a small blood sample to be applied anywhere on the wide yellow-highlighted tip, intuitively marked by red blood droplets near the area.
- Excellent accuracy (10/10): the Accu-Chek Guide system complies with ISO 15197:2013/EN ISO 15197:2015 and offers accuracy superior to the required standards, ensuring reliable results.
Technical specifications:
| Capillary sample aspiration | Yes |
| Reading time | <4 seconds |
| Measurement range | 10-600 mg/dl |
| Temperature range | 4-45°C |
| Operating humidity range | 10-90% |
| Hematocrit range | 10-65% |
| Use at altitude | Yes up to 3094 m above sea level |
| Biological fluid used for the sample | Capillary, venous, neonatal, and arterial blood |
| Minimum sample volume | 0.6 µl |
| Capillary absorption | Yes |
| Sampling method | Automatic absorption by aspiration of blood sample |
| Test reading principle | Electrochemical - Glucose Dehydrogenase (GDH) FAD dependent enzyme |
| Blood glucose meter to be used | Accu-Chek Guide |
System Accuracy:
1. System accuracy results for glucose concentrations below 100 mg/dL (below 5.55 mmol/L):
- within ±5 mg/dL (within ±0.28 mmol/L): 175/186 (94.1%);
- within ±10 mg/dL (within ±0.56 mmol/L): 186/186 (100%);
- within ±15 mg/dL (within ±0.83 mmol/L): 186/186 (100%).
2. System accuracy results for glucose concentrations at or above 100 mg/dL (at or above 5.55 mmol/L):
- within ±5 mg/dL: 296/414 (71.5%);
- within ±10 mg/dL: 404/414 (97.6%);
- within ±15 mg/dL: 413/414 (99.8%);
3. System accuracy results for glucose concentrations between 14 mg/mL (0.78 mmol/L) and 578 mg/mL (32.1 mmol/L):
- within ±15 mg/dL or within ±15% (within ±0.83 mmol/L or within ±15%): 599/600 (99.8%).
Components
Reagent composition:
Mediator 6.6%;
FAD-GDH Enzyme 21.3%;
Buffer 22.6%;
Stabilizer 0.3%;
Non-reactive component 49.2%;
How to use
Carefully read the test strip leaflet.
Place the sample on the strip's aspiration area, highlighted in yellow. Wait approximately 4 seconds for the measurement cycle to complete.
The yellow reactive zone on the strip provides visual confirmation of correct sample application.
Warnings
Lipemic samples (triglycerides) >1800 mg/dL (>20.3 mmol/L) may produce elevated blood glucose results.
Do not use this system if you are receiving an intravenous ascorbic acid infusion.
Do not use this system during a xylose absorption test.
Storage
Store the strips at a temperature between 4°C and 30°C.
Test strips can be used until the expiry date indicated on the packaging.
This applies to test strips in a new and intact vial, as well as to test strips in an already opened vial.
Format
Pack of 25 strips.
Code. 08137358001