FISIOCHAMBER VISION PLUS

INFANT 0-3 years

Description
Antistatic chamber for use with pressurized metered dose inhalers (MDIs).

Instructions for use
Before use, carefully check all parts, valves and air vents. Replace if defective.
Remove the cap from the metered dose inhaler (MDI). Shake the MDI.
Insert the MDI into the "Proper Fit" universal adapter and ensure a good seal.
Remove the cap from the inhalation chamber.
Insert the mask into the mouthpiece of the inhalation chamber.
Verify that the safety exhalation valve opens (otherwise replace the mask).
Apply the mask to the face and ensure a good seal.
If the patient can cooperate, apply the mouthpiece only in the mouth and ensure it is sealed correctly.
Inhale and exhale normally.
Then press the inhaler only once and begin to inhale slowly.
Carefully observe the VISION VALVE: its movement indicates the act of inhalation.
After pressing the inhaler, keep the mask firmly against the face for at least 5 breaths.
Before pressing the inhaler again, wait and repeat this step following the inhaler's or doctor's instructions. Always follow the dosage prescribed by the doctor.

Cleaning, disinfection and sterilization
Wash before first use and at least once a week following the instructions.
Remove all parts as indicated and open the chamber.
Submerge the parts for 15 minutes in clean warm water and mild detergent.
Shake gently.
Rinse all parts with clean water. Shake off excess water and leave to air dry.
Do not use fabrics to dry.
Before reassembling, ensure that the parts are thoroughly dry.
Reassemble the parts as indicated.
Disinfection: immerse in 3% hydrogen peroxide for 30 minutes.
Sterilization: sterilizable with a steam cycle at 121 °C or with ETO gas or with a plasma system.

Warnings
- Always follow the instructions before each use.
- Do not leave Fisio Chamber Vision or its parts within reach of children: some parts are small enough to be swallowed.
- The product must be replaced after a maximum of 2 years of continuous use.
- Replace the product when it is no longer in its original usable condition, due to any damage, valve seal integrity, environmental and storage conditions, and frequency of use.
- The use and sale of Fisio Chamber Vision are permitted under strict supervision of trained personnel.
- Monitor the patient during use.
- To maintain maximum efficiency of the device, we recommend replacing the valve block every 12 months.

Storage
Store the product in a dry and clean place.
Relative humidity 30% - 80%.
Storage temperature 0 °C-40 °C.
Avoid prolonged exposure to high temperatures.
Do not expose to: organic solvents, ionizing radiation, ultraviolet light, direct light, and sunlight.
Shelf life of intact packaging: 60 months.
Shelf life after opening: 24 months.

Code. KM 1322B