Description
Infrared thermometer.

How to use
- Please ensure the measuring sensor is not dirty, damaged, or scratched before use.
- Please ensure the ambient temperature is between 15 °C and 35 °C and that there are no factors that could interfere with temperature measurement before use.
- Please do not take measurements immediately after bathing or showering, after physical activity, after eating, or after sun exposure, otherwise the measurement result may be incorrect.
- Please do not take measurements in uncertain and/or rapidly changing environmental conditions or in precarious hygienic conditions, otherwise the measurement result may be inaccurate.
- Please ensure that the device and the patient have acclimatized to the same environmental conditions for at least 30 minutes at the time of measurement.
1. Press the ON/OFF button once to turn on the device.
2. After 3 seconds, the thermometer is ready in measurement mode and the blue LED indicator and the °C (or °F) symbol on the screen will flash.
3. Then bring the device close to and rest it on the forehead to automatically start temperature detection.
4. After 1 second, the measurement is complete and indicated by a specific audible and visual alert.
5. The device switches off automatically after 30 seconds of inactivity or manually by holding down the ON/OFF button until the device turns off.
A new measurement can be taken immediately when the blue LED light and the °C (°F) symbol flash again.
- Please hold the thermometer correctly against the forehead. Otherwise, the measurement may not be reliable and it would be necessary to remove the thermometer and repeat it.
Cleaning and disinfection methods
Before and after use, to clean the thermometer probe area, use 75% alcohol applied to a cotton swab, then dry with a soft cloth. Clean the thermometer regularly once a month.

Warnings
- This device is only intended for measuring body temperature, but it does not provide an assessment of clinical and health status. Therefore, please always follow your doctor's instructions.
Self-diagnosis could be dangerous and harmful.
Dirty infrared sensors can cause inaccurate measurements.
- Clean the sensor with common alcohol after use.
- Please do not touch or press the infrared sensor.
Damaged or dirty infrared sensors can cause inaccurate measurement results.
When the infrared sensor is dirty, use cotton swabs or a soft cloth moistened with alcohol to clean it very gently.
- Using toilet paper or paper tissues to clean the sensor could damage it and consequently cause an inaccurate measurement.
- Do not take measurements after a hot bath, prolonged sun exposure, or intense physical exertion. In these cases, the temperature measured by the device may be higher than the actual temperature.
- In cold weather, do not measure temperature immediately after returning home.
*Wait for the forehead to warm up. In this case, or after sleeping with pillows/hot water bottles, if you do not wait for a natural warming (thermal acclimatization) of the forehead, the measured temperature may be lower than the actual temperature.
- Do not attempt to disassemble and/or repair the thermometer.
- Do not store the thermometer in a place subject to splashes, high temperature, humidity, direct sunlight, dust, or corrosion. This product cannot be used in the aforementioned environments.
- Do not dispose of the product as normal waste. Comply with national disposal regulations. Dispose of batteries in appropriate containers.

Contraindications
- In case of battery ingestion, contact a doctor immediately.
- Do not use the thermometer in water or during excessive physical exertion.
- Measure temperature only on intact skin. Avoid using the device on the body area if it is inflamed or has trauma, wounds, or post-operative lesions.
- When reporting the measured temperature to your doctor, it is advisable to inform them that it was taken with an infrared thermometer.
- Please do not use this product in places other than the forehead.
- Please do not hit, break, step on, or shake the device body. - Please do not use this product in environments with significant electromagnetic interference.
- Please do not dismantle, repair, or deform the product.
- Please do not introduce liquids (alcohol, hot water, etc.) into the device.
- Anything that does not follow the above instructions may lead to an incorrect measurement result.